Past events
Past events
Results
Fully-matching results
-
12.2: Satellite constellations for positioning
https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-12-gps-systems/12.2-satellite-constellations-for-positioning24 Jan 2025: Top. Global Navigation Satellite System (GNSS). The Global Navigation Satellite System (GNSS) is a constellation of satellites orbiting the Earth that can determine the geographic location of a user’s receiver anywhere in the world. It covers all
- a:
- Grains Research and Development Corporation
- b:
- Grains Research and Development Corporation
- Date:
- 2025-01-24 14:40:37, 2025-01-24 14:40:37, 2024-12-02, 2025-01-24
- e:
- 12.2: satellite constellations for positioning, summary
- f:
- text/html
- H:
- ba22a8881abe592ecc9fe2b1f6e497a8
- j:
- https://grdc.com.au
- l:
- https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
- issueno:
- 12.2: Satellite constellations for positioning
- title:
- 12.2: Satellite constellations for positioning
- p:
- Grains Research and Development Corporation
- aissueno:
- Module 12: GPS systems
- thumbfocus:
- thumb-focus-center
- ctype:
- GrowNotes
-
11.18: General plumbing tips for installing hoses and fittings
https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.18-general-plumbing-tips-for-installing-hoses-and-fittings24 Jan 2025: Top. Always try to reduce all possible ‘blind spots’ where product may become trapped, never use reducing nipples or T-pieces on the inlet or outlet of a pump. To ensure components are easy to access and maintain, consider using some of the
- a:
- Grains Research and Development Corporation
- b:
- Grains Research and Development Corporation
- Date:
- 2025-01-24 14:40:36, 2025-01-24 14:40:36, 2024-11-29, 2025-01-24
- e:
- 11.18: general plumbing tips for installing hoses and fittings, summary
- f:
- text/html
- H:
- d00ea80d939fe6f3ef373b3f3fed69e7
- j:
- https://grdc.com.au
- l:
- https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
- issueno:
- 11.18: General plumbing tips for installing hoses and fittings
- title:
- 11.18: General plumbing tips for installing hoses and fittings
- p:
- Grains Research and Development Corporation
- aissueno:
- Module 11: Pumps, plumbing and components
- thumbfocus:
- thumb-focus-center
- ctype:
- GrowNotes
-
11.17: Examples of common plumbing configurations and tips
https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.17-examples-of-common-plumbing-configurations-and-tips24 Jan 2025: Top. Unfortunately, many of the ways that sprayers get plumbed do not allow all of the components to work as they were intended. Figures 1, 2, 3 and 4 provide examples of how different pump types and valve configurations can be plumbed to ensure
- a:
- Grains Research and Development Corporation
- b:
- Grains Research and Development Corporation
- Date:
- 2025-01-24 14:40:36, 2025-01-24 14:40:36, 2024-11-29, 2025-01-24
- e:
- 11.17: examples of common plumbing configurations and tips, summary
- f:
- text/html
- H:
- 0ce3c0344858c43067e915377dfff444
- j:
- https://grdc.com.au
- l:
- https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
- issueno:
- 11.17: Examples of common plumbing configurations and tips
- title:
- 11.17: Examples of common plumbing configurations and tips
- p:
- Grains Research and Development Corporation
- aissueno:
- Module 11: Pumps, plumbing and components
- thumbfocus:
- thumb-focus-center
- ctype:
- GrowNotes
-
11.16: Boom section control
https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.16-boom-section-control24 Jan 2025: Top. There are section-control systems available that can control either multiple boom sections or individual nozzles. The number of boom sections is generally only limited by the number of boom switches and boom valves fitted to the sprayer, and
- a:
- Grains Research and Development Corporation
- b:
- Grains Research and Development Corporation
- Date:
- 2025-01-24 14:40:36, 2025-01-24 14:40:36, 2024-11-29, 2025-01-24
- e:
- 11.16: boom section control, summary
- f:
- text/html
- H:
- e6daa9b0e169381af6cadccc8eb6b60c
- j:
- https://grdc.com.au
- l:
- https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
- issueno:
- 11.16: Boom section control
- title:
- 11.16: Boom section control
- p:
- Grains Research and Development Corporation
- aissueno:
- Module 11: Pumps, plumbing and components
- thumbfocus:
- thumb-focus-center
- ctype:
- GrowNotes
-
11.15: Pressure gauges
https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.15-pressure-gauges24 Jan 2025: Top. It is important to have two pressure gauges on each spray rig. One of the pressure gauges should be used to show the spray operator the pressure at the pump and the other used to show the pressure at the nozzle. The gauge showing pressure at
- a:
- Grains Research and Development Corporation
- b:
- Grains Research and Development Corporation
- Date:
- 2025-01-24 14:40:36, 2025-01-24 14:40:36, 2024-11-29, 2025-01-24
- e:
- 11.15: pressure gauges, summary
- f:
- text/html
- H:
- 7cbb11bae135f22170fb31051f463526
- j:
- https://grdc.com.au
- l:
- https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
- issueno:
- 11.15: Pressure gauges
- title:
- 11.15: Pressure gauges
- p:
- Grains Research and Development Corporation
- aissueno:
- Module 11: Pumps, plumbing and components
- thumbfocus:
- thumb-focus-center
- ctype:
- GrowNotes
-
11.14: Hydraulics for the pump and plumbing system
https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.14-hydraulics-for-the-pump-and-plumbing-system24 Jan 2025: Top. Hydraulic drive is the best way to drive a diaphragm pump as there are generally too many issues with using PTO-driven shafts, particularly for the safety of the operator. Diaphragm pumps (540 RPM models) that are hydraulically driven need to
- a:
- Grains Research and Development Corporation
- b:
- Grains Research and Development Corporation
- Date:
- 2025-01-24 14:40:36, 2025-01-24 14:40:36, 2024-11-29, 2025-01-24
- e:
- 11.14: hydraulics for the pump and plumbing system, summary
- f:
- text/html
- H:
- a8c85b77eb6deee321ea815ad2819ac3
- j:
- https://grdc.com.au
- l:
- https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
- issueno:
- 11.14: Hydraulics for the pump and plumbing system
- title:
- 11.14: Hydraulics for the pump and plumbing system
- p:
- Grains Research and Development Corporation
- aissueno:
- Module 11: Pumps, plumbing and components
- thumbfocus:
- thumb-focus-center
- ctype:
- GrowNotes
-
11.13: Boom re-circulation
https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.13-boom-re-circulation24 Jan 2025: Top. The main reason to consider boom re-circulation is the ability to prime the boom line with the tank mix before having to turn the nozzles on. This eliminates the need to flush the tank mix through the boom line in the paddock. Boom
- a:
- Grains Research and Development Corporation
- b:
- Grains Research and Development Corporation
- Date:
- 2025-01-24 14:40:35, 2025-01-24 14:40:35, 2024-11-29, 2025-01-24
- e:
- 11.13: boom re-circulation, summary
- f:
- text/html
- H:
- ad2d84e9fbec8db1e9a5e55fcb4a1c84
- j:
- https://grdc.com.au
- l:
- https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
- issueno:
- 11.13: Boom re-circulation
- title:
- 11.13: Boom re-circulation
- p:
- Grains Research and Development Corporation
- aissueno:
- Module 11: Pumps, plumbing and components
- thumbfocus:
- thumb-focus-center
- ctype:
- GrowNotes
-
11.12: Number of outlets on the nozzle body
https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.12-number-of-outlets-on-the-nozzle-body24 Jan 2025: Top. Operators will generally be offered a choice by the sprayer manufacturer regarding the number of nozzle outlets they require per nozzle body. Nozzle bodies are commonly available with one, two, three, four or five outlets. Five-nozzle body.
- a:
- Grains Research and Development Corporation
- b:
- Grains Research and Development Corporation
- Date:
- 2025-01-24 14:40:35, 2025-01-24 14:40:35, 2024-11-29, 2025-01-24
- e:
- 11.12: number of outlets on the nozzle body, summary
- f:
- text/html
- H:
- d6981752c0214e9c400f5b45f8592da9
- j:
- https://grdc.com.au
- l:
- https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
- issueno:
- 11.12: Number of outlets on the nozzle body
- title:
- 11.12: Number of outlets on the nozzle body
- p:
- Grains Research and Development Corporation
- aissueno:
- Module 11: Pumps, plumbing and components
- thumbfocus:
- thumb-focus-center
- ctype:
- GrowNotes
-
11.11: Non-drip check valves
https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.11-non-drip-check-valves24 Jan 2025: Top. Always check the pressure rating of non-drip check valves before purchase or installation. A TeeJet non-drip check valve. Always check the pressure rating that the non-drip valves will open and close at. Photo: TeeJet. (364.4 KB JPG). Enlarge
- a:
- Grains Research and Development Corporation
- b:
- Grains Research and Development Corporation
- Date:
- 2025-01-24 14:40:35, 2025-01-24 14:40:35, 2024-11-29, 2025-01-24
- e:
- 11.11: non-drip check valves, summary
- f:
- text/html
- H:
- da7b9b497c15c24dc46faab043dfe36b
- j:
- https://grdc.com.au
- l:
- https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
- issueno:
- 11.11: Non-drip check valves
- title:
- 11.11: Non-drip check valves
- p:
- Grains Research and Development Corporation
- aissueno:
- Module 11: Pumps, plumbing and components
- thumbfocus:
- thumb-focus-center
- ctype:
- GrowNotes
-
11.10: Nozzle bodies and mounting
https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.10-nozzle-bodies-and-mounting24 Jan 2025: Top. There are two common ways that nozzle bodies can be mounted: as a dry boom mount or a wet boom mount. Wet boom nozzle bodies are clamped onto a tube (the spray line) and dry boom bodies are connected by hose. Plumbing matching nozzle spacing
- a:
- Grains Research and Development Corporation
- b:
- Grains Research and Development Corporation
- Date:
- 2025-01-24 14:40:35, 2025-01-24 14:40:35, 2024-11-29, 2025-01-24
- e:
- 11.10: nozzle bodies and mounting, summary
- f:
- text/html
- H:
- fe09b74f87ef3709cfacc6c0fdc135d0
- j:
- https://grdc.com.au
- l:
- https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
- issueno:
- 11.10: Nozzle bodies and mounting
- title:
- 11.10: Nozzle bodies and mounting
- p:
- Grains Research and Development Corporation
- aissueno:
- Module 11: Pumps, plumbing and components
- thumbfocus:
- thumb-focus-center
- ctype:
- GrowNotes