Past events

Past events

GRDC search collection (meta), Funnelback Search
Contents
Metadata
Published
Display
per page
Located
km
Within

241 - 250 of 10,142 search results for

Results

  1. 12.2: Satellite constellations for positioning

    https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-12-gps-systems/12.2-satellite-constellations-for-positioning

    24 Jan 2025: Top. Global Navigation Satellite System (GNSS). The Global Navigation Satellite System (GNSS) is a constellation of satellites orbiting the Earth that can determine the geographic location of a user’s receiver anywhere in the world. It covers all

    a:
    Grains Research and Development Corporation
    b:
    Grains Research and Development Corporation
    Date:
    2025-01-24 14:40:37, 2025-01-24 14:40:37, 2024-12-02, 2025-01-24
    e:
    12.2: satellite constellations for positioning, summary
    f:
    text/html
    H:
    ba22a8881abe592ecc9fe2b1f6e497a8
    j:
    https://grdc.com.au
    l:
    https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
    issueno:
    12.2: Satellite constellations for positioning
    title:
    12.2: Satellite constellations for positioning
    p:
    Grains Research and Development Corporation
    aissueno:
    Module 12: GPS systems
    thumbfocus:
    thumb-focus-center
    ctype:
    GrowNotes
  2. 11.18: General plumbing tips for installing hoses and fittings

    https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.18-general-plumbing-tips-for-installing-hoses-and-fittings

    24 Jan 2025: Top. Always try to reduce all possible ‘blind spots’ where product may become trapped, never use reducing nipples or T-pieces on the inlet or outlet of a pump. To ensure components are easy to access and maintain, consider using some of the

    a:
    Grains Research and Development Corporation
    b:
    Grains Research and Development Corporation
    Date:
    2025-01-24 14:40:36, 2025-01-24 14:40:36, 2024-11-29, 2025-01-24
    e:
    11.18: general plumbing tips for installing hoses and fittings, summary
    f:
    text/html
    H:
    d00ea80d939fe6f3ef373b3f3fed69e7
    j:
    https://grdc.com.au
    l:
    https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
    issueno:
    11.18: General plumbing tips for installing hoses and fittings
    title:
    11.18: General plumbing tips for installing hoses and fittings
    p:
    Grains Research and Development Corporation
    aissueno:
    Module 11: Pumps, plumbing and components
    thumbfocus:
    thumb-focus-center
    ctype:
    GrowNotes
  3. 11.17: Examples of common plumbing configurations and tips

    https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.17-examples-of-common-plumbing-configurations-and-tips

    24 Jan 2025: Top. Unfortunately, many of the ways that sprayers get plumbed do not allow all of the components to work as they were intended. Figures 1, 2, 3 and 4 provide examples of how different pump types and valve configurations can be plumbed to ensure

    a:
    Grains Research and Development Corporation
    b:
    Grains Research and Development Corporation
    Date:
    2025-01-24 14:40:36, 2025-01-24 14:40:36, 2024-11-29, 2025-01-24
    e:
    11.17: examples of common plumbing configurations and tips, summary
    f:
    text/html
    H:
    0ce3c0344858c43067e915377dfff444
    j:
    https://grdc.com.au
    l:
    https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
    issueno:
    11.17: Examples of common plumbing configurations and tips
    title:
    11.17: Examples of common plumbing configurations and tips
    p:
    Grains Research and Development Corporation
    aissueno:
    Module 11: Pumps, plumbing and components
    thumbfocus:
    thumb-focus-center
    ctype:
    GrowNotes
  4. 11.16: Boom section control

    https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.16-boom-section-control

    24 Jan 2025: Top. There are section-control systems available that can control either multiple boom sections or individual nozzles. The number of boom sections is generally only limited by the number of boom switches and boom valves fitted to the sprayer, and

    a:
    Grains Research and Development Corporation
    b:
    Grains Research and Development Corporation
    Date:
    2025-01-24 14:40:36, 2025-01-24 14:40:36, 2024-11-29, 2025-01-24
    e:
    11.16: boom section control, summary
    f:
    text/html
    H:
    e6daa9b0e169381af6cadccc8eb6b60c
    j:
    https://grdc.com.au
    l:
    https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
    issueno:
    11.16: Boom section control
    title:
    11.16: Boom section control
    p:
    Grains Research and Development Corporation
    aissueno:
    Module 11: Pumps, plumbing and components
    thumbfocus:
    thumb-focus-center
    ctype:
    GrowNotes
  5. 11.15: Pressure gauges

    https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.15-pressure-gauges

    24 Jan 2025: Top. It is important to have two pressure gauges on each spray rig. One of the pressure gauges should be used to show the spray operator the pressure at the pump and the other used to show the pressure at the nozzle. The gauge showing pressure at

    a:
    Grains Research and Development Corporation
    b:
    Grains Research and Development Corporation
    Date:
    2025-01-24 14:40:36, 2025-01-24 14:40:36, 2024-11-29, 2025-01-24
    e:
    11.15: pressure gauges, summary
    f:
    text/html
    H:
    7cbb11bae135f22170fb31051f463526
    j:
    https://grdc.com.au
    l:
    https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
    issueno:
    11.15: Pressure gauges
    title:
    11.15: Pressure gauges
    p:
    Grains Research and Development Corporation
    aissueno:
    Module 11: Pumps, plumbing and components
    thumbfocus:
    thumb-focus-center
    ctype:
    GrowNotes
  6. 11.14: Hydraulics for the pump and plumbing system

    https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.14-hydraulics-for-the-pump-and-plumbing-system

    24 Jan 2025: Top. Hydraulic drive is the best way to drive a diaphragm pump as there are generally too many issues with using PTO-driven shafts, particularly for the safety of the operator. Diaphragm pumps (540 RPM models) that are hydraulically driven need to

    a:
    Grains Research and Development Corporation
    b:
    Grains Research and Development Corporation
    Date:
    2025-01-24 14:40:36, 2025-01-24 14:40:36, 2024-11-29, 2025-01-24
    e:
    11.14: hydraulics for the pump and plumbing system, summary
    f:
    text/html
    H:
    a8c85b77eb6deee321ea815ad2819ac3
    j:
    https://grdc.com.au
    l:
    https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
    issueno:
    11.14: Hydraulics for the pump and plumbing system
    title:
    11.14: Hydraulics for the pump and plumbing system
    p:
    Grains Research and Development Corporation
    aissueno:
    Module 11: Pumps, plumbing and components
    thumbfocus:
    thumb-focus-center
    ctype:
    GrowNotes
  7. 11.13: Boom re-circulation

    https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.13-boom-re-circulation

    24 Jan 2025: Top. The main reason to consider boom re-circulation is the ability to prime the boom line with the tank mix before having to turn the nozzles on. This eliminates the need to flush the tank mix through the boom line in the paddock. Boom

    a:
    Grains Research and Development Corporation
    b:
    Grains Research and Development Corporation
    Date:
    2025-01-24 14:40:35, 2025-01-24 14:40:35, 2024-11-29, 2025-01-24
    e:
    11.13: boom re-circulation, summary
    f:
    text/html
    H:
    ad2d84e9fbec8db1e9a5e55fcb4a1c84
    j:
    https://grdc.com.au
    l:
    https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
    issueno:
    11.13: Boom re-circulation
    title:
    11.13: Boom re-circulation
    p:
    Grains Research and Development Corporation
    aissueno:
    Module 11: Pumps, plumbing and components
    thumbfocus:
    thumb-focus-center
    ctype:
    GrowNotes
  8. 11.12: Number of outlets on the nozzle body

    https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.12-number-of-outlets-on-the-nozzle-body

    24 Jan 2025: Top. Operators will generally be offered a choice by the sprayer manufacturer regarding the number of nozzle outlets they require per nozzle body. Nozzle bodies are commonly available with one, two, three, four or five outlets. Five-nozzle body.

    a:
    Grains Research and Development Corporation
    b:
    Grains Research and Development Corporation
    Date:
    2025-01-24 14:40:35, 2025-01-24 14:40:35, 2024-11-29, 2025-01-24
    e:
    11.12: number of outlets on the nozzle body, summary
    f:
    text/html
    H:
    d6981752c0214e9c400f5b45f8592da9
    j:
    https://grdc.com.au
    l:
    https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
    issueno:
    11.12: Number of outlets on the nozzle body
    title:
    11.12: Number of outlets on the nozzle body
    p:
    Grains Research and Development Corporation
    aissueno:
    Module 11: Pumps, plumbing and components
    thumbfocus:
    thumb-focus-center
    ctype:
    GrowNotes
  9. 11.11: Non-drip check valves

    https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.11-non-drip-check-valves

    24 Jan 2025: Top. Always check the pressure rating of non-drip check valves before purchase or installation. A TeeJet non-drip check valve. Always check the pressure rating that the non-drip valves will open and close at. Photo: TeeJet. (364.4 KB JPG). Enlarge

    a:
    Grains Research and Development Corporation
    b:
    Grains Research and Development Corporation
    Date:
    2025-01-24 14:40:35, 2025-01-24 14:40:35, 2024-11-29, 2025-01-24
    e:
    11.11: non-drip check valves, summary
    f:
    text/html
    H:
    da7b9b497c15c24dc46faab043dfe36b
    j:
    https://grdc.com.au
    l:
    https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
    issueno:
    11.11: Non-drip check valves
    title:
    11.11: Non-drip check valves
    p:
    Grains Research and Development Corporation
    aissueno:
    Module 11: Pumps, plumbing and components
    thumbfocus:
    thumb-focus-center
    ctype:
    GrowNotes
  10. 11.10: Nozzle bodies and mounting

    https://grdc.com.au/resources-and-publications/grownotes/technical-manuals/spray-application-manual/spraying-system-components-and-set-up/module-11-pumps,-plumbing-and-components/11.10-nozzle-bodies-and-mounting

    24 Jan 2025: Top. There are two common ways that nozzle bodies can be mounted: as a dry boom mount or a wet boom mount. Wet boom nozzle bodies are clamped onto a tube (the spray line) and dry boom bodies are connected by hose. Plumbing matching nozzle spacing

    a:
    Grains Research and Development Corporation
    b:
    Grains Research and Development Corporation
    Date:
    2025-01-24 14:40:35, 2025-01-24 14:40:35, 2024-11-29, 2025-01-24
    e:
    11.10: nozzle bodies and mounting, summary
    f:
    text/html
    H:
    fe09b74f87ef3709cfacc6c0fdc135d0
    j:
    https://grdc.com.au
    l:
    https://grdc.com.au/__data/assets/image/0038/375887/brandmark_landscape.png
    issueno:
    11.10: Nozzle bodies and mounting
    title:
    11.10: Nozzle bodies and mounting
    p:
    Grains Research and Development Corporation
    aissueno:
    Module 11: Pumps, plumbing and components
    thumbfocus:
    thumb-focus-center
    ctype:
    GrowNotes

Pagination

Refine

Tools


Collection last updated: Feb 7, 2025, 4:00:06 AM.
Search powered by Funnelback.